ATTO Technology ExpressPCI FC 3321, FC 3322, F Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Vernetzung ATTO Technology ExpressPCI FC 3321, FC 3322, F herunter. ATTO Utilities - ATTO Technology Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
ATTO Technology, Inc.
ATTO Utilities
Installation and Operation Manual
ATTO Configuration Tool for Windows, Linux, Mac OS X
BIOS Utilities
ATTO Utilities for Windows
• Alamode
• Benchmark
• LUN Masking
• FC API
• Domain Validation
• ExpressRAID
© 2005 ATTO Technology, Inc. All rights reserved. All brand or product names are trademarks of their
respective holders. No part of this manual may be reproduced in any form or by any means without the
express written permission of ATTO Technology, Inc.
8/2005
.......................................................................
Document Control Number: PRMA-0267-000MD
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - ATTO Utilities

ATTO Technology, Inc.ATTO Utilities Installation and Operation ManualATTO Configuration Tool for Windows, Linux, Mac OS XBIOS UtilitiesATTO Utilities

Seite 2

1 ATTO Technology Inc. 1.0 ATTO Configuration ToolThe ATTO Configuration Tool is a utility program that displays information about installed adapters

Seite 3

2ATTO Utilities Installation and Operation ManualNavigating the ATTO Configuration ToolThe Device Listing window at the left of the display screen lis

Seite 4 - Contents

3 ATTO Technology Inc. Click on the Browse button at the bottom of the tab to search for new flash files on your system such as FlashBundle_2004_02_2

Seite 5

4ATTO Utilities Installation and Operation ManualExhibit 1-3 The Basic Info tab when a device is chosen from the Device Listing

Seite 6 - Sync Rate

5 ATTO Technology Inc.Exhibit 1-4 The Flash tabExhibit 1-5 The Advanced tab on Mac OS X for the UL3 and UL4 SCSI host bus adapter families

Seite 7

6ATTO Utilities Installation and Operation ManualExhibit 1-6 NVRAM screen when you highlight a channel in the Device Listing

Seite 8 - Glossary

7 ATTO Technology Inc.Exhibit 1-7 The PCI information page.

Seite 9

8ATTO Utilities Installation and Operation Manual 1.1 Fibre Channel NVRAM settingsThe settings in the NVRAM tab vary depending upon the selected adap

Seite 10 - 1.0 ATTO Configuration Tool

9 ATTO Technology Inc.Device DiscoveryChoices: Node WWN, Port WWNDefault: Node WWNSpecifies the type of device discovery the adapter performs. Use the

Seite 11 - - . In OS X

10ATTO Utilities Installation and Operation ManualLoop Arbitration FairnessChoices: Enabled, DisabledDefault: EnabledLoop arbitration fairness is an a

Seite 13

11 ATTO Technology Inc. 1.2 SCSI NVRAM settingsThe settings in the NVRAM tab vary depending upon the selected adapter and the operating system. ATTO

Seite 14 - Exhibit 1-4 The Flash tab

12ATTO Utilities Installation and Operation ManualQuick Arbitrate & Select (Ultra320 only)Choices: Disabled, EnabledDefault: EnabledIf enabled, im

Seite 15

13 ATTO Technology Inc. 1.3 TroubleshootingYou may see an error message informing you about an unexpected event or incorrect information discovered b

Seite 16

14ATTO Utilities Installation and Operation Manual

Seite 17 - CAUTIONCAUTION

15 ATTO Technology Inc. 2.0 BIOS Configuration UtilityThe BIOS driver for all ATTO host adapters has a built-in BIOS Configuration Utility which mana

Seite 18 - FCSW/3300/3305 adapters

16ATTO Utilities Installation and Operation Manualdevice, change the Enable Selectable Boot to No, then press the spacebar again to see the candidate

Seite 19

17 ATTO Technology Inc. 2.1 FC BIOS Configuration UtilityDefault NVRAM settings work for most applications, but your particular hardware configuratio

Seite 20 - 1.2 SCSI NVRAM settings

18ATTO Utilities Installation and Operation Manualframe size should be set to the largest value for normal operation. However, some older devices may

Seite 21

19 ATTO Technology Inc. 2.2 SCSI BIOS Configuration UtilityThe default NVRAM settings work for most applications, but your particular hardware config

Seite 22 - 1.3 Troubleshooting

20ATTO Utilities Installation and Operation ManualReset Bus on StartupChoices: Yes, NoDefault: YesIf enabled, the SCSI bus is reset upon adapter initi

Seite 24

21 ATTO Technology Inc.Sync RateChoices: varies by adapter, see Exhibit 2.2-1Default: varies by adapter, see Exhibit 2.2-1If synchronous transfers are

Seite 25

22ATTO Utilities Installation and Operation Manual

Seite 26

23 ATTO Technology Inc. 3.0 ATTO Utilities for WindowsThe ATTO Utilities for Windows is a collection of programs that provide adapter management, dev

Seite 27

24ATTO Utilities Installation and Operation Manual 3.1 Configuring Mode Pages: Alamode UtilityAlamode.exe is a Windows utility to optimize disk drive

Seite 28

25 ATTO Technology Inc. 3.2 ATTO Disk BenchmarkThe ATTO Utilities for Windows suite includes a utility for benchmarking drives to measure peak and su

Seite 29

26ATTO Utilities Installation and Operation Manualtestfile: Opens and executes the test named testfile with the extension .bmk or .tst (prior version

Seite 30 - Default: Yes

27 ATTO Technology Inc. 3.3 FC LUN Masking UtilityATTO host adapter drivers allow you to select which devices and Logical Unit Numbers (LUNs) on a SA

Seite 31

28ATTO Utilities Installation and Operation Manual• You may need to run Windows Disk Administrator (Windows NT) or the Volume Manager (Windows 2000)

Seite 32

29 ATTO Technology Inc. 3.4 SNIA FC Host Adapter APIAPI, or Application Programming Interface, is a set of commands used by an application directing

Seite 33

30ATTO Utilities Installation and Operation Manual

Seite 34 - 3.2 ATTO Disk Benchmark

ATTO Technology Inc.ContentsGlossary 1.0 ATTO Configuration Tool ...1To install from the

Seite 35 - /p textfile:

31 ATTO Technology Inc. 3.5 Domain Validation TestingDomain Validation tests the physical connection between host adapter and devices to ensure that

Seite 36 - 3.3 FC LUN Masking Utility

32ATTO Utilities Installation and Operation ManualExhibit 3.5-1 The Domain Validation Utility screen.

Seite 37

33 ATTO Technology Inc. 3.6 ExpressPCI SCSI Setup UtilityThe ExpressPCI Setup Utility changes the same NVRAM parameters as described for the ATTO Con

Seite 38 - • event notification

34ATTO Utilities Installation and Operation Manual

Seite 39

35 ATTO Technology Inc. 3.7 ATTO ExpressRAIDATTO ExpressRAID, which can be purchased from your ATTO dealer, creates virtual disk arrays on physical d

Seite 40

36ATTO Utilities Installation and Operation ManualATTO striping provides interleave sizes from 2KB to 512KB (default setting is 64KB). Please refer to

Seite 41

37 ATTO Technology Inc. 3.7.1 Installing ExpressRAIDThe ATTO ExpressRAID application runs under the Windows NT, Windows 2000, Windows XP, Windows Ser

Seite 42

38ATTO Utilities Installation and Operation Manual 3.7.2 Creating a RAID 0 GroupIf you plan to boot from a stripe group and there is a disk error, yo

Seite 43

39 ATTO Technology Inc. 3.8 TroubleshootingThe following suggestions may help if you are having problems.• Using the Device Manager, ensure that all

Seite 44 - 3.7 ATTO ExpressRAID

40ATTO Utilities Installation and Operation Manual

Seite 45

ATTO Utilities Installation and Operation ManualAn error occurred updating the NVRAM.Feature bounds checkingMessages from Flash Tab ActionsThis is not

Seite 46

i ATTO Technology Inc.Appendix A Contact ATTO Technology, Inc.Customer service, sales information and technical support are available by phone Monday

Seite 47

ATTO Technology Inc.Quick Arbitrate & Select (Ultra320 only)Reset Bus on StartupSCSI TerminationSelection TimeoutSCSI device settingsParameters p

Seite 48 - 3.8 Troubleshooting

ATTO Utilities Installation and Operation ManualInstallation requirementsATTO recommendationsInstallation instructions 3.7.2 Creating a RAID 0 Group

Seite 49

ATTO Technology Inc.GlossarySome terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology

Seite 50

ATTO Utilities Installation and Operation Manualhost a processor, usually a CPU and memory, which communicates with devices over an interfaceinitiator

Kommentare zu diesen Handbüchern

Keine Kommentare