Seitenansicht 5
2 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-84EN Adapter
The ATTO Celerity FC-84EN leverages two next-
generation storage technologies: PCIe 2.0
interconnect and 8-Gigabit Fibre Channel.
With 8-Gb FC speeds of up to 1600 MB/sec. per
channel, the Celerity FC-84EN supports the most
demanding application requirements, including high-
definition video, rich content databases and other
high-bandwidth environments.
ATTO Celerity host adapters are an integrated family
of advanced storage connectivity solutions that are
designed to provide reliable connectivity, intelligence
and scalability.
Technical specifications
4 independent Fibre Channel ports
8-Gigabit data transfer rates
1600 MB/sec. maximum full-duplex throughput
per channel
Supports all FC topologies: fabric, arbitrated
loop and point-to-point
ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
• Buffer credits: 41
ATTO Advanced Data Streaming (ADS™)
Technology
Advanced FC capabilities
Supports SNIA HBA API
Backward compatible with 4-Gb and 2-Gb Fibre
Channel
• Supports target and initiator modes
• Supports Windows®
FDMI and WMI
Host bus specifications
x8 mechanical and x8 electrical PCI Express
interconnect
Conforms to PCI Express Base Spec 2.0
Conforms to PCI Express CEM Spec 2.0
PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 6.6 inches
Height: 3.987 inches
Operating temperature: 0-40 ºC (32-113 ºF)
Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
Relative humidity: 10 to 90% non-condensing
• 7.8 W (typical)
100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
Easy to install full height connection bracket
External LEDs for on-line and speed status for
each channel
Four pluggable 8-Gb optical LC SFP+ modules
included
Software specifications
Windows 7®, XP®, Vista®
Windows Server® 2003, 2008
Mac® OS X 10.4.x and up
RedHat Enterprise Linux®
4.x (2.6.x kernesl)
RedHat Enterprise Linux®
5.x (2.6.x kernels)
RedHat Enterprise Linux®
6.x (2.6.x kernels)
• SUSE Linux Enterprise® 9.x (2.6.x kernels)
SUSE Linux Enterprise® 10.x (2.6.x kernels)
Fedora Core Linux® 7.x (2.6.x kernels)
Fedora Core Linux® 8.x (2.6.x kernels)
VMware ESX Server® 3.5 - 4.1